Chemical LIMS Software for Petrochemical and Chemical Industries
Quality control of raw materials, in-process samples and finished products, with specifications per grade and certificates of analysis that cannot be issued early. CORPEX LIMS, with an ERP interface built for your plant.
What a Chemical LIMS Is For
A chemical plant lives or dies on the QC laboratory’s verdict. Raw material arrives in tankers, drums or bags and cannot be used until it has been sampled and released. Intermediates are held at in-process checks. Finished product leaves only with a certificate of analysis that the customer will compare against the order. Each decision rests on the same things: the right sample, the right method, the right specification for that grade, a result no one can quietly change, and a clear record of who released what.
That is the job of LIMS software. CORPEX LIMS was built for regulated quality control, and the controls it brings to that work (versioned specifications, method control, review before release, a tamper-evident audit trail) are the ones a petrochemical or specialty chemical laboratory needs for its customers and for ISO/IEC 17025 accreditation.
QC of Raw Materials, Intermediates and Finished Products
The module handles a sample from registration to release for raw materials, in-process items and finished goods. For incoming material in particular it covers the points that go wrong in practice:
- Sampling plans per material. A plan states how many containers are identity-tested (all of them, a fixed number, a percentage or none) and how the composite is drawn; the default composite rule is the square root of the number of containers plus one. Containers are numbered, so the number written on the drum is the number on the record.
- Lot inspection levels. The Z1.4 (ISO 2859-1) single-sampling tables are built in, with the inspection level held per product and optionally per supplier.
- Supplier certificate against your result. The sampling record keeps the supplier’s CoA reference, the review of it, and whether it matches what the laboratory found.
- A decision, not just a verdict. The laboratory conclusion (conforms or not) is separate from the usage decision: Accept, Conditional, Reject or Rework. Only Accept and Conditional permit release; a rejected or reworked lot does not leave quarantine. The decision is taken after technical review, never in place of it.
Specifications per Grade, Under Version Control
Chemical products are sold by grade, and each grade has its own limits. In CORPEX LIMS a specification is a controlled record with a type (raw material, in-process, finished product, packaging, stability and others), a version, an effective date and a status that moves from Draft through approval to Effective and then Superseded. A grade is configured as its own product or material with its own specification, so the limits that apply to a sample are the limits of that grade at the date of testing.
Acceptance criteria are not limited to a maximum. The criteria types include minimum, maximum, range, target with absolute or percentage tolerance, equal, not equal, qualitative, categorical and yes/no, which covers the usual mix of assay, density, water content and appearance lines on a product data sheet. The specification can carry a market country and a source such as a pharmacopoeia, a customer or an in-house standard.
ASTM and ISO Methods as a Configured Method Library
Methods of analysis are kept as controlled records with a code, a status, an effective date and a review due date, and a version lineage. Each test in the test master points to its default method, its unit and decimals, and the technique an analyst must be qualified in to perform it.
Standard methods are licensed to your laboratory, so the library holds the methods you are licensed to use: your ASTM or ISO test methods and your in-house procedures, entered or imported during implementation and linked to the tests that use them.
Results can come from the instrument rather than a keyboard. An analyst presses Capture on a numeric worksheet field, and the reading arrives through the instrument inbox with its raw payload stored. The value is never converted: a reading in the wrong unit is refused rather than silently changed, and an instrument that is not usable (for example out of calibration) cannot be selected. Folder watching picks up result files from a data system’s export folder by a simple file pattern.
Certificates of Analysis for Chemical Products
A certificate of analysis cannot be issued while any test lacks a result or any result lacks a review, and it cannot be issued for a lot whose usage decision does not permit release. A certificate for a lot that has not been released is watermarked DRAFT, and copies for people who are not the issuer are marked as information copies, not for release. The test names printed on an issued certificate are a snapshot, so renaming a test later never rewrites a document already sent to a customer.
Out-of-specification results are flagged at entry and investigated with corrective and preventive action, and the annual product review and statistical process control draw on the same results.
How the LIMS Works With Your ERP
The LIMS answers whether the material is good. Your ERP knows what it is, where it is and what it cost. They are separate products with a defined interface between them. When you run SAP or another ERP, the interface (typically material and batch master data into the LIMS, and the usage decision and certificate status back) is designed, built and validated during the integration project against your configuration, rather than installed as a pre-built connector.
Genealogy, meaning which raw material lot went into which production batch, belongs on the ERP and manufacturing side. The LIMS carries the batch number, the containers and the results that decide the lot’s fate. For CORPEX’s own ERP, see CORPEX-ERP; for the integration approach, see LIMS and SAP integration.
Safety Data, Documents and Microbiology
Laboratory chemicals and prepared solutions carry a GHS classification taken from the supplier’s safety data sheet (hazard statements, pictograms and signal word) with the pictogram precedence rules applied, and a solution’s classification is rolled up from its ingredients as a labelled worst case. Quality documents such as SOPs and change control sit in the quality management system, a separate product. Where a plant also tests for microbiological quality, such as cooling or process water, the Microbiology and EM module runs on the same LIMS.
Chemical LIMS: Frequently Asked Questions
What is chemical LIMS software?
Chemical LIMS software manages the quality control laboratory of a chemical or petrochemical plant: sampling and testing of raw materials, in-process samples and finished products, specifications per grade, method control, instrument results and certificates of analysis.
How are ASTM and ISO methods handled?
As controlled records in the method library: you enter or import the ASTM, ISO or in-house methods you are licensed to use, keep them under version control and link them to the tests that use them.
How are specifications handled for different product grades?
Each grade is configured as its own product or material with its own specification. A specification has a version, an effective date and an approval status, and its acceptance criteria can be limits, ranges, targets with tolerance, or qualitative values.
Can a certificate of analysis be issued before release?
No. It cannot be issued while any test lacks a result or review, or for a lot whose usage decision does not permit release. A certificate for an unreleased lot is watermarked DRAFT.
How does the LIMS work with an ERP such as SAP?
They are separate products with a defined interface. There is no pre-built SAP connector: the interface for material and batch data and for release status is designed, built and validated in the integration project.
Can instruments send results to the LIMS?
Readings are captured into ELN worksheet fields from the instrument, and result files can be picked up from a data system's export folder. A reading in the wrong unit is refused rather than converted.
Talk to Us About Your Chemical Laboratory
Tell us your products, grades and methods and we will show CORPEX LIMS configured for them.